<LAN hardware address> may require a specific format for your system. For example:

In Windows NT 4.0 or Windows 2000:

arp -s 192.168.45.39 00-01-E6-a2-31-98 ping 192.168.45.39

In UNIX:

arp-s 192.168.45.39 00:01:E6:a2:31:98 ping 192.168.45.39

Note:

Once the IP address has been set on the print server, additional arp and ping commands will be ignored. Once the IP address is configured, arp and ping cannot be used unless the print server is reset to factory values (see cold

reset).

On UNIX systems, the arp -scommand may vary between different systems.

Some BSD-based systems expect the IP address (or host name) in reverse order. Other systems may require additional parameters. See your system documentation for specific command formats.

©2000, 2001 Hewlett-Packard Company