HP 175X, 310X Novell/NetWare Protocol Information, ENSNAP EN802.3, Rcvd, Message, Description

Models: 310X

1 202
Download 202 pages 6.17 Kb
Page 121
Image 121
Status

Status

Node Name

Primary

Frame

Type

Network

Frame

Type EN_II EN_802.2

EN_SNAP EN_802.3

Rcvd

Back to Top

Indicates the current IPX/SPX protocol status.

Ready the print server is awaiting data over IPX/SPX.

Disabled IPX/SPX was manually disabled.

Initializing the print server is registering the node address or name. An additional status message may also be displayed.

An error code and message are displayed if the print server is not ready.

[This line appears here only for the 175x

For the 310x, this line appears in the Novell/NetWare section instead.]

The IPX/SPX name of the print server. The default name is NPIxxxxxx, where xxxxxx is the last six digits of the LAN hardware (MAC) address.

Specifies the frame type selection on the print server.

Auto Select the print server automatically senses and limits the frame type to the first one detected.

EN_II limits the frame type to IPX over Ethernet frames. All others will be counted and discarded.

EN_802.2 limits the frame type to IPX over IEEE 802.2 with IEEE 802.3 frames. All others will be counted and discarded.

EN_SNAP limits the frame type to IPX over SNAP with IEEE 802.3 frames. All others will be counted and discarded.

EN_802.3 limits the frame type to IPX over IEEE 802.3 frames. All others will be counted and discarded.

The first column “Network” indicates the network number associated with each protocol frame type used for communication between a server and the print server.

Unknown the print server is still trying to determine which network number to use.

The second column “Frame Type” identifies the frame type associated with each network number.

Unless a specific frame type has been manually configured, the print server automatically determines the protocol frame type by listening to the network data being transferred over the network.

Disabled a specific frame type for that network has been manually configured.

The third column “Rcvd” indicates how many packets have been received for each frame type.

Novell/NetWare Protocol Information

Provides the current status and parameter values for the Novell NetWare network protocol.

This section appears only for the 310x.

Message

Description

Page 121
Image 121
HP 175X Novell/NetWare Protocol Information, Status Node Name Primary Frame Type Network Frame Type ENII EN802.2, Rcvd