Side-edge adjustment for the glass
Hint |
| It might be helpful to reset the product settings to factory defaults before attempting manual | |
|
| calibration. Be sure to print a configuration page before doing a setting reset so that any user- | |
|
| defined settings can be restored (see “Configuration page” on page 130). | |
|
|
|
|
| 1 | Press the MENU button. | |
| 2 | Select DIAGNOSTICS. | |
| 3 | Select CALIBRATE SCANNER. | |
| 4 | Select SIDE EDGE ADJUSTMENT GLASS. | |
| 5 | The message Side Edge Glass ### Range | |
|
|
| the numeric keypad to type a value for the |
|
|
| |
Hint |
| Entering a lower value than current setting moves the image away from the left edge (toward the | |
|
| right side of the page). Entering a higher value than the current setting moves the image toward | |
|
| the left edge of the page. | |
|
|
|
|
| 6 | Press the SELECT ( ) button to save the setting. | |
| 7 | Use the glass to scan a source document (use the calibration target page if you have already | |
|
|
| automatically calibrated the MFP). Verify that the image is correctly positioned on the output |
|
|
| copy |
50 Maintenance |