Side-edge adjustment for the glass

Hint

 

It might be helpful to reset the product settings to factory defaults before attempting manual

 

 

calibration. Be sure to print a configuration page before doing a setting reset so that any user-

 

 

defined settings can be restored (see “Configuration page” on page 130).

 

 

 

 

 

1

Press the MENU button.

 

2

Select DIAGNOSTICS.

 

3

Select CALIBRATE SCANNER.

 

4

Select SIDE EDGE ADJUSTMENT GLASS.

 

5

The message Side Edge Glass ### Range 0-255appears on the control-panel display. Use

 

 

 

the numeric keypad to type a value for the side-edge adjustment.

 

 

 

Hint

 

Entering a lower value than current setting moves the image away from the left edge (toward the

 

 

right side of the page). Entering a higher value than the current setting moves the image toward

 

 

the left edge of the page.

 

 

 

 

 

6

Press the SELECT ( ) button to save the setting.

 

7

Use the glass to scan a source document (use the calibration target page if you have already

 

 

 

automatically calibrated the MFP). Verify that the image is correctly positioned on the output

 

 

 

copy

50 Maintenance

C9148-90909