Scanner controller board

The scanner controller board controls the operation of flatbed and ADF components used in the following scanning processes: document transportation, document exposure, and imaging. When the copy processor board sends the scan commands to the scanner controller board, the scanner controller board sends signals to the motors, solenoids, scanning lamp, and CCD driver PCB.

The scanner controller board controls the operation of the following components:

ADF document transportation

ADF sensors (door-open, document-detect, and leading-edge sensors)

ADF solenoid

ADF drive motor

document exposure

optical-unit home-position sensor

scanning lamp

scanning motor

imaging process

CCD driver PCB (converts reflected light to a digital RGB signal)

copy processor communication

flatbed intake fan (off in PowerSave mode, half-speed when idle; full-speed when scanning)

 

ADF motor circuit

 

The ADF motor circuit controls the operation of the ADF motor. The ADF motor is a +24 vdc

 

stepping motor. It rotates in a counterclockwise direction. The ADF motor is not fault-protected.

 

 

Note

When a fault-protected motor circuit fails, an error message appears on the control panel. The

 

ADF motor circuit is not fault protected. No error message appears on the control-panel display

 

if this circuit fails.

 

 

 

Optical-unit motor circuit

 

The optical unit motor circuit controls the optical unit motor and the movement of the unit. The

 

optical unit motor is a +24 vdc stepping motor. It rotates in both a clockwise and

 

counterclockwise direction. If the optical unit motor fails, the message 30.1.17 SCAN FAILURE

 

appears on the control-panel display.

 

Scan-unit intake-fan motor circuit

 

The fan motor circuit controls the fan speed. The fan is off in PowerSave mode, it rotates at half-

 

speed when the product is idle, and at full-speed during the scanning process, when a document

 

is detected in the ADF, or when a control-panel button or key is pushed. If the fan motor fails, the

 

message 30.01.06 Scan Failure appears on the control panel-display.

C9148-90909

5 Theory of operation 61