Chapter 22: LPC24XX I2C interfaces I2C0/1/2
6.2 Master Receiver mode
In the master receiver mode, data is received from a slave transmitter. The transfer is
initiated in the same way as in the master transmitter mode. When the START condition
has been transmitted, the interrupt service routine must load the slave address and the
data direction bit to the I2C Data Register (I2DAT), and then clear the SI bit. In this case,
the data direction bit (R/W) should be 1 to indicate a read.
When the slave address and data direction bit have been transmitted and an
acknowledge bit has been received, the SI bit is set, and the Status Register will show the
status code. For master mode, the possible status codes are 0x40, 0x48, or 0x38. For
slave mode, the possible status codes are 0x68, 0x78, or 0xB0. For details, refer to
Table22–526.
After a repeated START condition, I2C may switch to the master transmitter mode.
Fig 112. Format in the Master Transmitter mode
A = Acknowledge (SDA low)
A = Not acknowledge (SDA high)
S = START condition
P = STOP condition
S SLAVE ADDRESS RW A DATA A A/A P
data transferred
(n Bytes + Acknowledge)
“0” - write
“1” - read
from Master to Slave
from Slave to Master
DATA
Fig 113. Format of Master Receive mode
DATA
A = Acknowledge (SDA low)
A = Not acknowledge (SDA high)
S = START condition
P = STOP condition
S SLAVE ADDRESS R A DATA P
data transferred
(n Bytes + Acknowledge)
“0” - write
“1” - read
from Master to Slave
from Slave to Master
AA