Topcon A2677 manual Guidance Sections, Valves, Nozzles Total

Models: A2677

1 268
Download 268 pages 19.43 Kb
Page 108
Image 108

X20 Sprayer Reference Manual

Guidance Sections

The Guidance sections are displayed on the Guidance screen and are used to produce the Coverage map. The Guidance sections are also used by Guidance to know how many sections are used by Auto Section Control (ASC).

Enter in the number of section valves on the primary line.

Valves

Hardi Sprayers require special hardware to operate. When fitting the Sprayer controller to an existing Hardi Sprayer, it needs to cater for their balanced valves.

Balanced valves, when closed, bypass the flow back to the tank instead of just stopping it. However, the flow back to tank is being calculated by the X20 console, therefore the system needs to know when all the section valves are switched OFF; the signal pulses from the Flow Meter are ignored.

Select Balanced when connecting the TPA system to a Hardi type Sprayer with Balanced valves.

Nozzles

Total

The total number of nozzles fitted on the primary line can be entered here. This number is used to calculate an average flow rate per nozzle which can be displayed on the Working screen.

The number of nozzles is also used to calculate the Minimum Flow.

The number of nozzles should be the number of primary line nozzles only, with the nozzle count for each section entered into the appropriate section.