X20 Sprayer Reference Manual

The Low Speed Shutoff for the secondary line (sections 9-16) would be all set at the same speed you require the secondary line to switch ON.

Setting the Number of Sections When Using a Primary Section Valve to Switch Secondary Line On

If the Spray Boom has been setup, for example with 5 sections on the primary line and a section valve to control the secondary line, then select the Lines as Single and the number of Sections as 6.

Then enter ‘5’ as the number of Guidance Sections.

Enter the section widths of each of the sections (1-5) and enter a zero width for the ‘6’ section.

See page 8-49 to set the Low Speed Shutoffs for section ‘6’, set the Low Speed Shutoff for section ‘6’ at the speed you require the secondary line to switch ON.

Widths

To enter the width for each Boom Section select the calculator icon. See Appendix A for help with using the calculator icon.

Only the number of sections selected will be displayed.

Each section has a calculator icon next to it. Select the calculator icon and enter in a value for each of the sections.

If all the sections are the same width then the Set All button can be used. Enter in the section width using the calculator keypad and select Enter, then all the sections will have that width value entered.

Select OK to close the Section Widths window when all section