Topcon A2677 manual Dump Valve must be located between the pump and Flow Meter

Models: A2677

1 268
Download 268 pages 19.43 Kb
Page 51
Image 51

X20 Sprayer Reference Manual

WARNING WARNING

If the Valve Harness needs the connectors replaced to suit the valve connectors, then you should ensure that the Sprayer Harness is disconnected from the Tractor Harness. Otherwise damage to the Spray ECU will occur, if the wires are shorted out during this procedure.

Connecting to the Dump Valve

The Dump Valve (not supplied in kit) is activated when all sections are switched OFF or when the Master Switch is switched OFF, this directs all the flow back to the tank.

NOTICE NOTICE

The Dump Valve must be located between the pump and Flow Meter.

1.Connect the ARAG connector labeled Dump 1 to the Dump Valve

TIP

TIP

If you notice that the Dump Valve is going in the wrong direction, you have to swap the wires in the Arag connector.

If the Dump Valve connector is on the Sprayer Harness, then an adaptor will be required to connect the 4-Pin Weather Pack to the Dump Valve. You must connect the correct adaptor to the Dump Valve. See Table 5-1 on page 5-24 to determine which adaptor you should use.

A2677 Rev 1.5

5-23

Page 51
Image 51
Topcon A2677 manual Dump Valve must be located between the pump and Flow Meter, Connecting to the Dump Valve