X20 Sprayer Reference Manual
WARNING WARNING
If the Valve Harness needs the connectors replaced to suit the valve connectors, then you should ensure that the Sprayer Harness is disconnected from the Tractor Harness. Otherwise damage to the Spray ECU will occur, if the wires are shorted out during this procedure.
Connecting to the Dump Valve
The Dump Valve (not supplied in kit) is activated when all sections are switched OFF or when the Master Switch is switched OFF, this directs all the flow back to the tank.
NOTICE NOTICE
The Dump Valve must be located between the pump and Flow Meter.
1.Connect the ARAG connector labeled Dump 1 to the Dump Valve
TIP
TIP
If you notice that the Dump Valve is going in the wrong direction, you have to swap the wires in the Arag connector.
If the Dump Valve connector is on the Sprayer Harness, then an adaptor will be required to connect the
A2677 Rev 1.5 |