Topcon A2677 manual Connecting to a Flow Meter

Models: A2677

1 268
Download 268 pages 19.43 Kb
Page 45
Image 45

X20 Sprayer Reference Manual

Connecting to a Flow Meter

The Flow Meter (not supplied in kit) is installed between the Regulator Valve and the Section Valves. The Flow Meter will be installed so that it measures only the quantity of liquid being delivered to the spray line.

NOTICE NOTICE

There must be no return line to tank or pump after the Flow Meter.

1.Connect the Flow Meter 3-Pin Connector to the 3-Pin connector marked Flow Meter 1 on the Sprayer Harness (Figure 5-5 on page 5-10)

NOTICE NOTICE

The Flow Meter may require a connector change to attach to the 3-Pin connector marked Flow Meter 1 on the Sprayer Harness. Refer to the Flow Meter manufacturer’s specifications for correct pin allocation.

CAUTION CAUTION

Care should be taken when replacing these connectors, not to damage the Sprayer Harness or Flow Meter and connectors should be fully circuit tested prior to installation.

A2677 Rev 1.5

5-17

Page 45
Image 45
Topcon A2677 manual Connecting to a Flow Meter