X20 Sprayer Reference Manual
•Section Switches—The section switches turn the Boom Sections ON or OFF. Up is OFF, down is ON
The red LEDs next to each section switch turn ON when spraying and flash when the Boom Section is switched ON but the Master switch is OFF.
The red LEDs next to each section also turn ON when the sprayer's ground speed drops below the Low Speed Shut Off value while the Boom Section is switched ON and the Master switch is ON
•Master Switch—turns all selected Boom Sections ON or OFF. Up is OFF, down is ON. This applies as long as the option on Page 8-30 'External Switch Up is ON' is not ticked
•Auto/Manual Switch—turns the system from automatic mode to manual. Up is Manual, down is Auto
•Increase/Decrease—Each toggle changes the rate either up or down by the preset Increment Rate whilst in the Auto mode. Up is increase, down is decrease
When in the manual mode it increases and decreases the system pressure. Up is increase, down is decrease
•Parallel Guidance—When using Guidance in conjunction with your Topcon Spray Rate Controller you can use this button in lieu of the PARALLEL button. You still must select point A and point B, on the screen
•Guide Lock—When using Guidance in conjunction with your Topcon Spray Rate Controller you can use this button in lieu of the GUIDE LOCK button on the guidance screen