Image 238

X20 Sprayer Reference Manual

Problem 14

Rate Unstable

Information

The X20 has a selection of Regulator valves specified by the manufacturer in the valve settings options. The Standard option suits all valves supplied by Topcon and many others with speeds varying from 6 seconds to 30 seconds.

The Max On Time is the maximum time power is applied to the valve to correct the rate. If the target rate and the current rate are widely different, this is the maximum time that the valve will be driven before power will be removed and if necessary, reapplied. If this value is too low, the system will be sluggish and slow to respond. The maximum value will suit most applications.

The Min On Time is the minimum or shortest time that the power will be applied to the Regulator Valve. The maximum value will also suit most systems. If set too low, the valve may not move when a small correction is required.

The PWM Setting varies the average voltage applied to the valve motor. At 100%, a full 12 Volts is applied, whereas at the lesser settings reduce the voltage to the percentage shown. The reduced voltage makes the valve turn slower and is helpful when trying to correct an overshooting problem with the faster valves, 6 seconds etc. The slow valves, 20 seconds, usually need to be 100% for good control.

The Gain Setting is simply like a volume control, how hard the controller is going to respond to changes required. The second level down will suit most applications.

The Micro-traksetting is designed for the Micro-trak Regulator Valve which is a fast control valve.