X20 Sprayer Reference Manual
•Micro-Trak—should be selected if a Micro-Trak Regulator Valve is used for regulation. When Micro-Trakis selected the settings are entered automatically into the Max On Time, PWM Setting, Min On Time and Gain Setting windows and are optimized for the Mictro-Trak Regulator Valve
•DICKEY-john—should be selected if a DICKEY- john Regulator Valve is used for regulation. When DICEKY-johnis selected the default settings are entered automatically into the Max On Time, PWM Setting, Min On Time and Gain Setting windows and are optimized for the DICKEY-john Regulator Valve
•Raven—should be selected if the Sprayer has Raven Fast Flow Regulator Valve fitted, unless a Topcon Pressure Relief (495181) has been fitted to the Raven Fast Flow Regulator Valve.
The Raven Fast Flow has a three way valve which acts as both a regulator and dump valve. The valve will go from fully closed to fully open in 1.5 seconds. The PWM Setting must be left on full (100%) otherwise this will impair
the operation of the Dump Valve and Automatic Section Control.
If Raven is selected you will have to enter the settings from Table 8-2 (page 8-19) into the Max On Time, PWM Setting, Min On Time and Gain Setting windows.