X20 Sprayer Reference Manual
Problem
Rate goes up when slowing down
Causes | Solutions | Tips | Additional Data |
20. Minimum | Check | There are 3 | Yes, see |
Flow settings | trigger points | minimum hold | Additional |
activated | for the | settings: Nozzle, | Data, Problem |
| minimum flow | Flow Meter and | 20, page |
| settings, may | Speed. When |
|
| be normal | activated, the |
|
| behaviour | Sprayer |
|
|
| switches to |
|
|
| Manual and |
|
|
| holds the |
|
|
| regulator at that |
|
|
| point |
|
Problem
Incorrect pressure reading
Causes | Solutions | Tips |
21. Regulator Faulty | Check and | If regulator is seized |
| repair regulator | there will be no |
|
| control. If at the end |
|
| of travel only |
|
| control in manual is |
|
| still possible. Check |
|
| other |
|
| configuration fac- |
|
| tors. |
www.topconpa.com |