Topcon A2677 manual Topcon Sensors, Sensor Input Test

Models: A2677

1 268
Download 268 pages 19.43 Kb
Page 193
Image 193

X20 Sprayer Reference Manual

State 2—Controller set to manual, sections and master ON, pressing and holding the decrease arrow (▼). The meter should display opposite to State 1.

Confirming this verifies the regulator outputs on the controller are working correctly.

Please note: If the Dump valve opens when it should close swap the wires connected to Pin-1 and Pin-2 in the connector (Figure 12-3 on page 12-4).

Topcon Sensors

Figure 12-4. Sensor Connector

All shaft sensor inputs (other references Flow Sensor, Speed Sensor, Encoder and Feedback) are pinned alike.

Each time the Sensor is exposed to magnetic field (Hall effect) or metallic objects (Proximity) the circuit is closed between Pin-A and Pin-B. The controller sees this as 0 Volts, then 5 Volts when the sensor is clear of the magnet or metallic object.

Sensor Input Test

1.Power ECU on

2.On the Harness with the sensor disconnected check:

11-12 Volts between Pin-B and Pin-C

A2677 Rev 1.5

12-5

Page 193
Image 193
Topcon A2677 manual Topcon Sensors, Sensor Input Test