X20 Sprayer Reference Manual

Regulator Valve Settings

Figure 8-5. Regulator Valve Settings

The Regulating Valves and their settings are critical for the correct operation of the Sprayer, particularly if Automatic Section Control (ASC) is to be used.

To have good control when using ASC a faster Regulator Valve may need to be installed. A 20 second KZCO Valve will be sluggish and give poor control when using ASC and should be updated to the 6 second ARAG Valve (grey band) or faster Regulator Valve. 6 seconds represents the time for the Reg Valve to go from fully closed to fully open.

When a Controller mode is selected then the Max On Time, PWM Setting, Min On Time and Gain Setting settings are automatically set. These settings can then be fine tuned manually.

Controller Mode

Select one of the following options:

Standard—will account for most regulating valve types available in the market. Standard mode takes into account