Topcon A2677 manual 17-2

Models: A2677

1 268
Download 268 pages 19.43 Kb
Page 224
Image 224

X20 Sprayer Reference Manual

 

To Fast

From Pump

Valve

Pressure

Skin fitting

to be fitted

Relief Outlet

to tank

Figure 17-1. Pressure Relief Valve Layout

The Pressure Relief Valve will be fitted between the pump in the pressure hose and the Fast Valve.

The Pressure Hose is a 1 ¼" hose; it will need to be cut to add the Pressure Relief Hose.

A Skin Fitting (supplied) must be fitted to the tank, for the relief chemical. Fit the Skin Fitting approximately 20 centimetres above the base of the tank, so that "frothing" does not occur and agitation is not enhanced.

The dealer/end users will have to supply an appropriate 1 ¼" chemi- cal resistant hose, to connect the Pressure Relief Outlet and the Skin Fitting. An appropriate hose clamp will also have to be supplied.

Once the pressure relief valve is fitted to the pump. Pressure Outlet Hose and then connected to the tank skin fitting, wind the Pressure Regulating Adjuster fully out, this will result in all fluids being "dumped".

17-2

www.topconpa.com

Page 224
Image 224
Topcon A2677 manual 17-2