Figure 17-2. Close Valve When Flow Off
When setting up the software make sure the Close Valve When Flow Off option (page
The controller mode must be selected as Standard (page
Setting the Pressure Relief
To adjust the Pressure Relief Valve you must know the correct working pressures applicable to the spray nozzles. The valve needs to be set at a point that will allow 1 Bar (approximately 100kpa) more than the nozzle maximum pressure.
1.Place water into the Sprayer
2.Start the pump
3.Place the controller into manual and press the Up arrow (▲) on the screen for 20 seconds