X20 Sprayer Reference Manual

Choosing the Correct Adaptor for the Dump Valve

Part No. Usage

 

Use if connecting to a 2-wire dump valve and 12V

A2266

is applied to the dump valve when the Master switch

 

is OFF

 

Use if connecting to a Solenoid Valve, with 6mm

A2267

spade terminals and 12V is applied to the dump

 

valve when the Master switch is OFF

A2268

Use if connecting to a 3-Wire Dump Valve and 12V

 

is applied to the Dump Valve when the Master is

 

OFF

 

Use when connecting to a 3-Wire Dump Valve and

A2269

12V is applied to the Dump Valve when the Master

 

is ON

Figure 5-1. How to Choose the Correct Adaptor for the

Dump Valve

2.When all the Arag connectors are in place, tighten the screw at the top of the Arag connector, using a screwdriver, to secure the connector to the Section and Dump Valves

3.Tidy any excess harness, using cable ties

To complete the installation go to page 5-31, to connect the Spray ECU Power/Comms Harness to the battery.