X20 Sprayer Reference Manual
Correction Factor After a Pressure Calibration is Unacceptable
If the Pressure Readout is less than the Pressure Gauge:
1. Add the difference
If the Pressure Readout is more than the Pressure Gauge:
1. Subtract the difference
Eg: If the Pressure Readout reads 400kpa and the Pressure Gauge reads 450kpa, add the difference of 50kpa to the Pressure Gauge reading during the next calibration: enter a correction factor of ‘500kpa’ using the screen keyboard.
1.Select RESTORE FACTORY DEFAULTS at the bottom of Tank Pressure window (Figure
2.Select CALIBRATE SENSOR in the Tank Pressure window (Figure
3.Follow the on screen directions to calibrate the Pressure Sensor.
When the pump is at operating pressure (eg: 450kpa) and the screen keyboard window appears, you will enter in the new correction factor, using the above formula (eg: ‘500’).
Manual Entry of Pressure Calibration Factors (Spray ECU Only)
Manual Entry of Pressure Calibration Factors can only be selected if Spray ECU was selected as the controller (page