Pump Options

Select Enable Pump Speed Indicator (Figure 8-16 on page

8-46) when a speed sensor is fitted to the pump to readout the RPM of the pump shaft.

If Enable Pump Speed Indicator is selected enter in a Min. and Max RPM value for the Pump Shaft (by selecting the relevant calculator icon). An alarm will be displayed when the pump speed falls below the set minimum RPM value and above the set maximum RPM value.

Enable Speed Smoothing

By default Enable Speed Smoothing is enabled. Under normal spraying operations this should not be changed.

If a need arises for faster response to vehicle acceleration and deceleration then deselect the box.

NOTICE NOTICE

The rate displayed on the screen may fluctuate more when the Enable Speed Smoothing option is disabled.