X20 Sprayer Reference Manual

Regulator Drive Test Procedure

1.Set a Digital Multimeter to measure 20vdc

2.Measure the voltage between Pin-1 and Pin-2 in the following states:

State 1—Controller set to manual, sections and master ON, pressing and holding the increase arrow (▲). The meter should display 12 or -12 Volts.

Please note: It is not important which polarity is displayed.

State 2—Controller set to manual, sections and master ON, pressing and holding the decrease arrow (▼). The meter should display opposite to State 1.

Confirming this verifies the regulator outputs on the controller are working correctly.

Please note: If the Spray-line pressure increases when the decrease arrow (▼) is pressed select Reverse Valve Direction (page 8-20).