X20 Sprayer Reference Manual
Please note: As a general rule the CONNECTOR 2 plug is only required if the Sprayer:
•Has more than 10 Boom Sections
•Has more than 2 tanks
•Is connecting to external switches which control the Boom Sections (boom sensing), eg: Boom Section switches on a T Bar or Joy Stick or other third party section switches.
Connector 3
Normally CONNECTOR 3 (16 pin) is only required if the Sprayer requires extra pressure inputs, tank level sensors and extra encoder inputs.
3-Pin Weather Pack Connector/Ground Speed
The Tractor Harness has a
Either an A328 Shaft/Speed Sensor Kit or A449 Radar Sensor Interface Harness (not included in this kit) can be connected to this connector.
Typically, the Radar Sensor Interface Harness would be connected to the Tractor Harness Ground Speed Connector.
NOTICE NOTICE
Only one speed connector can be used at any one time.
See "Connecting to a Speed Sensor", page
www.topconpa.com |