X20 Sprayer Reference Manual

Ground Speed, Fan Speed and Auxiliary Shaft Sensors

Ground Speed Sensor

Hall Effect type sensors

Fan Speed Sensor and

3-Pin Weather Pack Plug (Pin A, B and C)

Auxiliary Shaft Sensors

 

Sensor to Magnet

2-3 millimeters (mm)

Distance

 

Supply Voltage

Supply 12 Volts from Spray ECU

Signal Voltage

4-5 Volts sensor inactive

 

<1 Volt sensor activated by magnet

Flow Sensors

With switch OFF

Open Circuit

Switch ON Resistance

1800 Ohms

2 Wire only

 

Maximum Contact

50 milli-amps

Current

 

Accuracy

2% in range 10% to 200% of nominal flow

Bone

15mm

Nominal Flow Rate

80l/min

Calibration

45.7 pulse/l

14-2

www.topconpa.com

Page 204
Image 204
Topcon A2677 manual Ground Speed, Fan Speed and Auxiliary Shaft Sensors, Flow Sensors