Topcon A2677 manual Ground Speed, Fan Speed and Auxiliary Shaft Sensors, Flow Sensors

Models: A2677

1 268
Download 268 pages 19.43 Kb
Page 204
Image 204

X20 Sprayer Reference Manual

Ground Speed, Fan Speed and Auxiliary Shaft Sensors

Ground Speed Sensor

Hall Effect type sensors

Fan Speed Sensor and

3-Pin Weather Pack Plug (Pin A, B and C)

Auxiliary Shaft Sensors

 

Sensor to Magnet

2-3 millimeters (mm)

Distance

 

Supply Voltage

Supply 12 Volts from Spray ECU

Signal Voltage

4-5 Volts sensor inactive

 

<1 Volt sensor activated by magnet

Flow Sensors

With switch OFF

Open Circuit

Switch ON Resistance

1800 Ohms

2 Wire only

 

Maximum Contact

50 milli-amps

Current

 

Accuracy

2% in range 10% to 200% of nominal flow

Bone

15mm

Nominal Flow Rate

80l/min

Calibration

45.7 pulse/l