X20 Sprayer Reference Manual
Rate and Pressure
Problem
Rate Unstable
Causes | Solutions | Tips | Additional Data |
14. Regulator | Tune regulator | All setup steps | Yes, see |
settings | settings, check | can be done | Additional |
| correct valve | stationary with | Data, Problem |
| type is selected | manual speed | 14, page |
15. Faulty | Test and repair | Pump may be | Yes, see |
pump | pump | sucking air or | Additional |
|
| pulsing due to | Data, Problem |
|
| faulty valves | 15, page |
16. Faulty | Test and repair | Faulty Flow Me- | Yes, see |
Flow Meter | Flow Meter | ter (worn out) | Additional |
|
| or below Flow | Data, Problem |
|
| Meter minimum | 16, page |
|
| rate |
|
Problem
Wrong Pressure
Causes | Solutions | Tips |
17. Bad Flow Meter | Check Flow Meter | If Flow Meter |
calibration | calibration and type | calibration is |
| select | incorrect the |
|
| pressure for the rate |
|
| showing will be out. |
|
| Check nozzle charts |
www.topconpa.com |