Topcon A2677 manual X20 Sprayer Reference Manual

Models: A2677

1 268
Download 268 pages 19.43 Kb
Page 41
Image 41

X20 Sprayer Reference Manual

2.Mount the Shaft/Speed Sensor to an existing structure on the wheel axle, ideally in a protected position to face the magnet.

NOTICE NOTICE

The distance between the Shaft/Speed Sensor to Wheel Stud Magnet needs to be 2 to 3 mm (1/16 to 1/8 inch). The Shaft/Speed Sensor must be mounted so that the Wheel Stud Magnets pass the sensor evenly and squarely.

To mount the Shaft/Speed sensor you can either:

Use the Mounting Bracket Assemblies (slotted brackets and angle brackets with hose clamps) provided (Figure 5-7 on page 5-14)

Fabricate your own mounting bracket to suit the Sprayer chassis.

NOTICE NOTICE

There must be no movement of the sensor relative to the magnet.

A2677 Rev 1.5

5-13