X20 Sprayer Reference Manual
Settings for Raven Controller Mode
| Controller | Max On Time | PWM Setting | Min On Time |
| Gain Setting |
|
|
|
|
|
|
|
Raven |
|
|
|
|
|
|
Fast Flow | Raven | 40 msec. | 100% | 8 msec. |
| 2.4ms/% |
Reg valve |
|
|
|
|
|
|
(1.5 sec.) |
|
|
|
|
|
|
| Table |
|
CAUTION CAUTION
When using a Raven Regulator that operates as a Dump Valve then you must select the Close Valve When Flow Off option. Failure to do this could dead end the system and cause damage to pumps, hoses etc.
See "Service Bulletins", Chapter 7 if a positive displacement (piston or diaphragm) pump and a Raven Fast Flow Regulator Valve are fitted.
TPA recommends a Pressure Relief kit (495181) to be fitted to the Sprayer. If the kit is fitted then follow the settings recommended in the Service Bulletin.
A2677 Rev 1.5 |