X20 Sprayer Reference Manual

Settings for Raven Controller Mode

 

Controller

Max On Time

PWM Setting

Min On Time

 

Gain Setting

 

 

 

 

 

 

 

Raven

 

 

 

 

 

 

Fast Flow

Raven

40 msec.

100%

8 msec.

 

2.4ms/%

Reg valve

 

 

 

 

 

 

(1.5 sec.)

 

 

 

 

 

 

 

Table 8-2. Settings for Raven Controller Mode

 

CAUTION CAUTION

When using a Raven Regulator that operates as a Dump Valve then you must select the Close Valve When Flow Off option. Failure to do this could dead end the system and cause damage to pumps, hoses etc.

See "Service Bulletins", Chapter 7 if a positive displacement (piston or diaphragm) pump and a Raven Fast Flow Regulator Valve are fitted.

TPA recommends a Pressure Relief kit (495181) to be fitted to the Sprayer. If the kit is fitted then follow the settings recommended in the Service Bulletin.

A2677 Rev 1.5

8-19

Page 99
Image 99