Toshiba W7 Preset Speed #8, Preset Speed #9, Preset Speed #10, Preset Speed #11, Preset Speed #12

Models: W7

1 167
Download 167 pages 14.06 Kb
Page 108
Image 108

Preset Speed #8

 

 

Preset Speed #12

 

 

 

 

Preset Speed #8

 

 

 

Program

Preset Speeds

8

Parameter Type — Numerical

 

 

 

Factory Default — 0.00

This parameter assigns an output frequency to binary number 1000 and is

 

identified as Preset Speed #8. The binary number is applied to S1 S4 of the

Changeable During Run — Yes

Control Terminal Strip to output the Preset Speed (see Preset Speed #1 for

 

further information on this parameter).

Minimum — Lower Limit

 

 

 

 

 

Maximum — Upper Limit

 

 

 

 

 

Units — Hz

 

 

 

 

Preset Speed #9

 

 

 

Program

Preset Speeds

9

Parameter Type — Numerical

 

 

 

Factory Default — 0.0

This parameter assigns an output frequency to binary number 1001 and is

 

identified as Preset Speed #9. The binary number is applied to S1 S4 of the

Changeable During Run — Yes

Control Terminal Strip to output the Preset Speed (see Preset Speed #1 for

 

further information on this parameter).

Minimum — Lower Limit

 

 

 

 

 

Maximum — Upper Limit

 

 

 

 

 

Units — Hz

 

 

 

 

Preset Speed #10

 

 

 

Program

Preset Speeds

10

Parameter Type — Numerical

 

 

 

Factory Default — 0.00

This parameter assigns an output frequency to binary number 1010 and is

 

identified as Preset Speed #10. The binary number is applied to S1 S4 of the

Changeable During Run — Yes

Control Terminal Strip to output the Preset Speed (see Preset Speed #1 for

 

further information on this parameter).

Minimum — Lower Limit

 

 

 

 

 

Maximum — Upper Limit

 

 

 

 

 

Units — Hz

 

 

 

 

Preset Speed #11

 

 

 

Program

Preset Speeds

11

Parameter Type — Numerical

 

 

 

Factory Default — 0.00

This parameter assigns an output frequency to binary number 1011 and is

 

identified as Preset Speed #11. The binary number is applied to S1 S4 of the

Changeable During Run — Yes

Control Terminal Strip to output the Preset Speed (see Preset Speed #1 for

 

further information on this parameter).

Minimum — Lower Limit

 

 

 

 

 

Maximum — Upper Limit

 

 

 

 

 

Units — Hz

 

 

 

 

Preset Speed #12

 

 

 

Program

 

Preset Speeds

 

12

Parameter Type — Numerical

This parameter assigns an output frequency to binary number 1100 and is

Factory Default — 0.00

 

identified as Preset Speed #12. The binary number is applied to S1 S4 of the

Changeable During Run — Yes

Control Terminal Strip to output the Preset Speed (see Preset Speed #1 for

 

further information on this parameter).

Minimum — Lower Limit

 

 

 

Maximum — Upper Limit

 

 

 

Units — Hz