Input Terminal Priority

 

Interlock with ST

 

 

 

Input Terminal Priority

 

 

Program

Terminal Settings

Input Terminals Other Input

Parameter Type — Selection List

Terminal Priority Selection

 

Factory Default — Disabled

 

 

 

 

This parameter is used to allow the Jog or the DC Injection Braking input

Changeable During Run — No

signals to control the ASD when received via the Control Terminal Strip even

 

though the system is in the Local mode.

 

With this parameter enabled, a Jog command or a DC Injection Braking

 

command received from the Control Terminal Strip will receive priority over

 

commands from the keypad.

 

 

See Jog Run Frequency for further information on using the Jog function.

 

See DC Injection Braking Current for further information on this parameter.

 

Settings:

 

 

 

 

Enabled

 

 

 

Disabled

 

 

 

 

 

Inrush Current Suppression Time (MS Relay Delay)

 

Program

Protection Settings

Inrush Time

Parameter Type — Numerical

The startup inrush current may be suppressed for up to 2.5 seconds. This

Factory Default — 0.30

parameterdetermines the length of⇒⇒⇒the inrush current suppression.

Changeable During Run — No

 

 

 

 

Minimum — 0.30

 

 

 

 

Maximum — 2.50

 

 

 

 

Units — Seconds

 

 

 

Integral (I) Gain

 

 

Program

Feedback Settings

Integral Gain

Parameter Type — Numerical

This parameter determines the degree that the Integral function affects the

Factory Default — 0.10

 

output signal when using PID feedback to control the ASD output. The smaller

Changeable During Run — Yes

the value here, the more pronounced the effect of the integral function on the

 

output signal.

 

 

Minimum — 0.01

 

 

 

 

Maximum — 100.0

 

 

 

Interlock with ST

Interlock with ST

 

Program

Protection Settings

Parameter Type — Selection List

The MS1 AUX relay circuit is normally open and is in series with the ST-to-

Factory Default — Disabled

 

CC connection.

 

 

Changeable During Run — Yes

 

 

 

 

After normal system power is available the MS1 AUX relay circuit closes and

 

completes the ST-to-CCconnection.

 

Settings:

 

 

 

Disabled

 

 

Enabled

 

 

W7 ASD Installation

and Operation Manual

77

Page 83
Image 83
Toshiba W7 Input Terminal Priority, Inrush Current Suppression Time MS Relay Delay, Integral I Gain, Interlock with ST