Speed Drop Detection Frequency Range |
| Stall Prevention During Regeneration | |||||||
|
|
| |||||||
Speed Drop Detection Frequency Range |
|
| |||||||
Program | ⇒ | Protection Settings Speed Drop Detection Frequency | Parameter Type — Numerical | ||||||
Range |
|
| ⇒ |
|
| Factory Default — 0.00 | |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
While operating using PG feedback, this parameter sets the lower level of the | Changeable During Run — Yes | ||||||||
deviation limit that, once the output frequency falls below this setting, causes a | |||||||||
| |||||||||
Speed Drop Detected alert. |
|
|
|
| Minimum — 0.00 | ||||
|
|
|
|
|
|
|
| Maximum — 30.00 | |
|
|
|
|
|
|
|
| Units — Hz | |
|
|
|
| ||||||
Speed Reach Detection Band |
|
|
| ||||||
Program | ⇒ | Terminal Settings | ⇒ | Output Terminals Reach Speed | Parameter Type — Numerical | ||||
|
|
|
|
| ⇒⇒ |
| |||
Reach Detection Band |
|
|
|
| Factory Default — 2.5 | ||||
This parameter sets the bandwidth of the Speed Reach Frequency setting. | Changeable During Run — Yes | ||||||||
|
|
|
|
|
|
|
| Minimum — 0.0 | |
|
|
|
|
|
|
|
| Maximum — Max. Freq. | |
|
|
|
|
|
|
|
| Units — Hz | |
Speed Reach Setting Frequency |
|
| |||||||
Program |
| Output Terminals Speed Reach Setting Frequency | Parameter Type — Numerical | ||||||
This setting establishes a frequency threshold that, when reached or is within | Factory Default — 2.5 | ||||||||
the Reach Detection bandwidth, will provide a signal at an output terminal that | |||||||||
Changeable During Run — Yes | |||||||||
can close an appropriately configured output contact. |
| ||||||||
|
|
|
|
|
|
|
| Minimum — 0.0 | |
|
|
|
|
|
|
|
| Maximum — Max. Freq. | |
|
|
|
|
|
|
|
| Units — Hz | |
|
|
|
|
| |||||
Speed Reference Address |
|
|
|
| |||||
Program |
| Communication Settings S20 Settings | Parameter Type — Selection List | ||||||
The S20 system is Toshiba’s | Factory Default — 0 | ||||||||
| |||||||||
This function is unavailable at the time of this release. |
| Changeable During Run — No | |||||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| ||||
Speed Reference Station |
|
|
|
|
| ||||
Program |
| Communication Settings ⇒S20 Settings | Parameter Type — Selection List | ||||||
The S20 system is Toshiba’s | Factory Default — 0 | ||||||||
| |||||||||
This function is unavailable at the time of this release. |
|
| |||||||
| ⇒ |
|
| ⇒ |
|
|
| Changeable During Run — No | |
Stall Prevention During Regeneration |
|
| |||||||
Program |
| Protection Settings | Stall Prevention During | Parameter Type — Selection List | |||||
Regeneration |
|
|
|
|
| Factory Default — Disabled | |||
|
|
|
|
|
|
|
| ||
Enables/Disables the Overvoltage Stall |
|
|
| ||||||
during regeneration⇒ | only. | ⇒ | and the Overcurrent Stall function | Changeable During Run — No | |||||
126 |
|
|
|
|
| W7 ASD Installation and Operation Manual |