Motor Constant #5

 

 

 

Motor Type

 

 

 

 

 

Motor Constant #5

 

 

 

 

Program

Motor Settings

 

Motor Constant #5 (Leakage

Parameter Type — Numerical

Inductance)

 

 

 

Factory Default — (ASD-dependent)

 

 

 

 

 

This parameter is used to compensate for the affects of leakage inductance.

Changeable During Run — No

 

 

 

 

 

Increases in this setting results in slight increases in the output voltage of the

Minimum — 0.00

ASD at the high speed range.

 

 

 

 

 

 

 

This (motor tuning) setting is required to use the Vector Control, Automatic

Maximum — 650.0

Torque Boost, or Automatic Energy-saving functions.

Units — µH

 

 

 

 

 

 

 

Motor Shaft Stationary Control

 

Program

Protection Settings Motor Shaft Stationary Control

Parameter Type — Selection List

This parameter Enables/Disables a continuous DC injection at half of the

Factory Default — Disabled

 

amperage setting of the DC Injection Braking Current parameter into a

Changeable During Run — Yes

stopped motor. This feature is useful in preheating the motor or to keep a

 

stopped motor from spinning freely.

 

Motor Shaft Stationary Control starts after the DC injection brake stops the

 

motor and continues until ST-to-CCis opened, power is turned off, receiving an

 

Emergency Off command, or this parameter is changed.

 

To use this feature, a non-zero entry at the DC Injection Braking Start

 

Frequency⇒⇒parameter is required.

 

 

Motor Type

 

 

 

 

Program

Motor Settings

 

Motor Type

Parameter Type — Selection List

This parameter identifies the type of motor being used.

Factory Default — Toshiba EQP III

TEFC

 

 

 

 

Settings:

 

 

 

Changeable During Run — No

 

 

 

 

Toshiba EQP III TEFC

 

 

 

Toshiba EQP III ODP

 

 

 

Toshiba EPACT TEFC

 

 

 

ToshibaEPACT ODP

 

 

Other Motor

 

 

 

86