Motor Constant #5 |
|
|
| Motor Type | ||
|
|
|
|
| ||
Motor Constant #5 |
|
|
|
| ||
Program | Motor Settings |
| Motor Constant #5 (Leakage | Parameter Type — Numerical | ||
Inductance) |
|
|
| Factory Default — | ||
|
|
|
|
| ||
This parameter is used to compensate for the affects of leakage inductance. | Changeable During Run — No | |||||
|
|
|
|
| ||
Increases in this setting results in slight increases in the output voltage of the | Minimum — 0.00 | |||||
ASD at the high speed range. |
|
|
| |||
|
|
|
| |||
This (motor tuning) setting is required to use the Vector Control, Automatic | Maximum — 650.0 | |||||
Torque Boost, or Automatic | Units — µH | |||||
|
|
|
|
| ||
|
| |||||
Motor Shaft Stationary Control |
| |||||
Program | Protection Settings Motor Shaft Stationary Control | Parameter Type — Selection List | ||||
This parameter Enables/Disables a continuous DC injection at half of the | Factory Default — Disabled | |||||
| ||||||
amperage setting of the DC Injection Braking Current parameter into a | Changeable During Run — Yes | |||||
stopped motor. This feature is useful in preheating the motor or to keep a | ||||||
| ||||||
stopped motor from spinning freely. |
| |||||
Motor Shaft Stationary Control starts after the DC injection brake stops the |
| |||||
motor and continues until |
| |||||
Emergency Off command, or this parameter is changed. |
| |||||
To use this feature, a |
| |||||
Frequency⇒⇒parameter is required. |
|
| ||||
Motor Type |
|
|
|
| ||
Program | Motor Settings |
| Motor Type | Parameter Type — Selection List | ||
This parameter identifies the type of motor being used. | Factory Default — Toshiba EQP III | |||||
TEFC | ||||||
|
|
|
| ⇒ | ||
Settings: |
|
|
| Changeable During Run — No | ||
|
|
|
| |||
Toshiba EQP III TEFC |
|
|
| |||
Toshiba EQP III ODP |
|
|
| |||
Toshiba EPACT TEFC |
|
|
| |||
Toshiba⇒EPACT ODP | ⇒ |
|
| |||
Other Motor⇒ |
|
|
|
86 | W7 ASD Installation and Operation Manual |