Low Output Disable Start Level

 

 

 

 

Maximum Output Voltage #1

 

 

 

 

Low Output Disable Start Level

 

 

 

Program

PID Setup Low-output Disable Start Level

 

Parameter Type — Numerical

 

 

 

 

 

 

Factory Default — 0.0

The Low Output Disable Start Level sets the output frequency threshold that,

 

if exceeded, will initiate the LOD function if properly configured.

 

Changeable During Run — Yes

 

 

 

 

 

 

 

 

Minimum — 0.0

 

 

 

 

 

 

 

 

Maximum — Max. Freq.

 

 

 

 

 

 

 

 

Units — Hz

Low Speed Signal Output Frequency

 

 

Program

 

Terminal Settings

Output Terminals Low Speed

Parameter Type — Numerical

Signal Output Frequency

 

 

 

 

 

Factory Default — 0.0

 

 

 

 

 

 

 

 

This parameter sets the low-speed trip threshold.

 

Changeable During Run — Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum — 0.0

 

 

 

 

 

 

 

 

Maximum — Upper Limit

 

 

 

 

 

 

 

 

Units — Hz

 

 

 

 

 

 

 

Main EEPROM Version

 

 

 

 

 

 

Program

 

Utilities Versions

Main Board EEPROM Version

 

This is a read-only parameter that displays the Main EEPROM version.

 

 

 

 

 

 

Maximum Output Frequency

 

 

 

 

Program Fundamental Parameters

Fundamental #1

Maximum

Parameter Type — Numerical

Output Frequency

 

 

 

⇒⇒

 

Factory Default — 80.0

 

 

 

 

 

 

 

 

 

 

 

 

 

This setting determines the absolute maximum frequency that the ASD can

Changeable During Run — No

output. This setting is also referred to as FH.

 

 

 

Accel/deceltimes are calculated based

on the MaximumFrequency setting.

Minimum — 30.0

Note: This setting may not be lower than the Upper Limit setting.

Maximum — 299.0

 

 

 

 

 

 

 

 

 

Units — Hz

 

 

 

 

 

Maximum Output Voltage #1

 

 

 

 

Program

 

Fundamental Parameters

Fundamental #1

Maximum

Parameter Type — Numerical

Output Voltage #1

 

 

 

 

 

Factory Default — (ASD dependent)

 

 

 

 

 

 

 

 

This parameter sets the maximum value of the output voltage of the ASD for

Changeable During Run — Yes

the #1 Motor Set.

value,the output voltage cannot be higher than

 

Regardless of the programmed

Minimum — 0.0

the input voltage.

 

 

 

 

 

Maximum — (ASD dependent)

 

 

 

 

 

 

 

 

The actual output voltage will be influenced by the input voltage of the ASD

Units — Volts

and the Supply Voltage Compensation parameter setting.

 

 

 