Commercial (Power) Wait Time

 

 

Communication Interval (TTL)

 

 

 

 

Commercial (Power) Wait Time

 

 

 

Program

 

Special Control Comm Wait Time

Parameter Type — Selection List

This parameter determines the amount of time that the drive will wait before

Factory Default — 0.62

allowing commercial power to be applied to the motor once the switch-to-

Changeable During Run — No

commercial-power criteria has been met.

 

 

 

 

 

 

 

 

 

 

Minimum — 0.37

 

 

 

 

 

Maximum — 10.00

 

 

 

 

 

Units — Seconds

 

 

 

 

Communications Data Type

 

 

 

Program

 

Communication Settings

 

Communication Data Type

Parameter Type — Selection List

In the event of a communication error during a transmission, the command that

Factory Default — 0

was transmitted may be cleared or held.

 

 

Changeable During Run — No

 

 

 

Changes made to this parameter require that the power be cycled (Off then On)

 

for the changes to take effect.

 

 

 

Settings:

 

 

 

 

 

0 — Command Request Cleared

 

 

 

1 — Command Request Held

 

 

 

 

 

 

 

Communication Interval (TTL)

 

 

 

Program

Communication Settings

TTL Res Time

Parameter Type — Numerical

 

 

 

Factory Default — 0.00

This parameter sets the TTL response delay time.

 

Changes made to this parameter require that the power be cycled (Off then On)

Changeable During Run — Yes

for the changes to take effect.

 

 

Minimum — 0.00

 

 

 

 

 

 

Maximum — 2.00

 

 

 

Units — Seconds

62

W7 ASD Installation and Operation Manual

Page 68
Image 68
Toshiba W7 manual Communications Data Type, Communication Interval TTL, Commercial Power Wait Time, Communication Data Type