Torque Boost #3 |
|
| Trip Save at Power Down Enable | |||
|
|
|
| |||
Torque Boost #3 |
|
|
| |||
Program |
| Motor Settings | Torque Boost #3 | Parameter Type — Numerical | ||
The Motor #3 Torque Boost function is used to increase the low frequency | Factory Default — | |||||
| ||||||
torque for high inertia loads by increasing the output voltage at frequencies | Changeable During Run — Yes | |||||
below ½ of the #3 Base Frequency setting. | ||||||
| ||||||
This parameter is used only when the parameters for motor set #3 are | Minimum — 0.0 | |||||
| ||||||
configured and selected. Motor set #3 may be selected by a properly configured | Maximum — 30.0 | |||||
input terminal. |
|
| ||||
|
|
| ||||
See parameter Motor #1 Torque Boost for more information on this setting. | Units — % | |||||
| ||||||
|
|
|
| |||
Torque Boost #4 |
|
|
| |||
Program | ⇒ | Motor Settings | Torque Boost #4 | Parameter Type — Numerical | ||
|
|
| ⇒ | Factory Default — | ||
The Motor #4 Torque Boost function is used to increase the low frequency |
| |||||
torque for high inertia loads by increasing the output voltage at frequencies | Changeable During Run — Yes | |||||
below ½ of the #4 Base Frequency setting. |
| |||||
This parameter is used only when the parameters for motor set #4 are | Minimum — 0.0 | |||||
configured and selected. Motor set #4 may be selected by a properly configured | Maximum — 30.0 | |||||
input terminal. |
|
|
| |||
See parameter Motor #1 Torque Boost for more information on this setting. | Units — % | |||||
⇒ | ⇒ |
| ||||
Torque Reference | Address |
| ||||
Program |
| Communication Settings Torque Reference Address | Parameter Type — Selection List | |||
The S20 system is Toshiba’s | Factory Default — 0 | |||||
| ||||||
This function is unavailable at the time of this release. |
| |||||
|
| |||||
Torque Reference Station |
| |||||
Program |
| Communication Settings Torque Reference Station | Parameter Type — Selection List | |||
The S20 system is Toshiba’s | Factory Default — 0 | |||||
|
This function is unavailable at the time of this release.
Transmit Address
Program Communication Settings ⇒Transmit Address
The S20 system is Toshiba’s
Parameter Type — Selection List Factory Default — 0
Trip Save at Power Down Enable
Program ⇒Protection Settings Trip Save at Power Down
This parameter Enables/Disables the⇒Trip Save at Power Down setting. When enabled, this feature logs the trip event and retains the trip information when the system powers down. The trip information may be viewed from the Monitor screen.
When disabled, the trip information will be cleared when the system powers down.
130
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
W7 ASD Installation and Operation Manual