Toshiba W7 manual Program Special Control Startup Frequency

Models: W7

1 167
Download 167 pages 14.06 Kb
Page 133
Image 133

Startup Frequency

Startup Frequency

Startup Frequency

Program Special Control Startup Frequency

The outputof the ASD will remainat 0.0 Hz until the programmed speed value exceeds this setting during startup. Once exceeded during startup, the output frequency of the ASD will accelerate to the programmed setting.

Output frequencies below the Startup Frequency will not be output from the ASD during startup. However, once reaching the Startup Frequency, speed values below the Startup Frequency may be output from the ASD.

Parameter Type — Numerical

Factory Default — 0.10

Changeable During Run — Yes

Minimum — 0.0

Maximum — 10.0

Units — Hz

W7 ASD Installation and Operation Manual

127

Page 133
Image 133
Toshiba W7 manual Program Special Control Startup Frequency