RR Torque Reference Setpoint #1 | RR Torque Reference Setpoint #2 |
RR Torque Reference Setpoint #1
Program Frequency Settings RR RR Torque Reference
Setpoint #1
This parameter is used to set the gain and bias of the RR input terminal when the RR terminal is used as the control input while operating in the Torque Control mode.
RR Input Torque Control Setup
Perform the following setup to allow the system to receive Torque control input at the RR input terminal:
• | Program Utilities | Command and Frequency Settings Command |
| Mode Select Terminal Block. | |
• | Program ⇒Utilities ⇒Command and Frequency Settings ⇒Frequency#1 | |
| Mode Select ⇒RR. |
|
• | Provide a Run command (F and/or R). |
Torque Control
Perform the following setup to allow the system to perform Torque control from the RR input terminal:
• | Set RR Torque Reference #1, |
• | Set the RR⇒input signal level (RR⇒⇒Speed Ref #1) that represents the RR |
| Torque Reference #1, |
• | Set RR Torque Reference #2, and |
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
Torque Settings
•Set the RR input signal level (RR Speed Ref #2) that represents the RR Torque Reference #2.
This is accomplished by establishing an associated V/f output pattern for a given RR input level.
This parameter sets RR Torque Reference #1 and is the output torque value that is associated with the setting of RR Speed Reference #1 when operating in the Torque control mode.
This value is entered as 0.0 to 250% of the output torque range.
RR Torque Reference Setpoint #2
Program Frequency Settings | RR RR Torque Reference |
⇒ | ⇒⇒ |
Setpoint #2 |
|
This parameter is used to set the gain and bias of the RR input terminal when the RR terminal is used as the control input while operating in the Torque Control mode.
This is accomplished by establishing an associated V/f output pattern for a given RR input level.
See RR Torque Reference #1 for further information on this setting.
This parameter sets RR Torque Reference #2 and is the output torque value that is associated with setting of RR Speed Reference #2 when operating in the Torque control mode.
This value is entered as 0.0 to 250% of the output torque range.
W7 ASD Installation and Operation Manual
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Yes
Minimum — 0.0
Maximum — 250.0
Units — %
109