Toshiba W7 manual RR Torque Reference Setpoint #1, RR Torque Reference Setpoint #2

Models: W7

1 167
Download 167 pages 14.06 Kb
Page 115
Image 115

RR Torque Reference Setpoint #1

RR Torque Reference Setpoint #2

RR Torque Reference Setpoint #1

Program Frequency Settings RR RR Torque Reference

Setpoint #1

This parameter is used to set the gain and bias of the RR input terminal when the RR terminal is used as the control input while operating in the Torque Control mode.

RR Input Torque Control Setup

Perform the following setup to allow the system to receive Torque control input at the RR input terminal:

Program Utilities

Command and Frequency Settings Command

 

Mode Select Terminal Block.

Program Utilities Command and Frequency Settings Frequency#1

 

Mode Select RR.

 

Provide a Run command (F and/or R).

Torque Control

Perform the following setup to allow the system to perform Torque control from the RR input terminal:

Set RR Torque Reference #1,

Set the RRinput signal level (RR⇒⇒Speed Ref #1) that represents the RR

 

Torque Reference #1,

Set RR Torque Reference #2, and

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.0

Maximum — 250.0

Units — %

Torque Settings

Set the RR input signal level (RR Speed Ref #2) that represents the RR Torque Reference #2.

This is accomplished by establishing an associated V/f output pattern for a given RR input level.

This parameter sets RR Torque Reference #1 and is the output torque value that is associated with the setting of RR Speed Reference #1 when operating in the Torque control mode.

This value is entered as 0.0 to 250% of the output torque range.

RR Torque Reference Setpoint #2

Program Frequency Settings

RR RR Torque Reference

⇒⇒

Setpoint #2

 

This parameter is used to set the gain and bias of the RR input terminal when the RR terminal is used as the control input while operating in the Torque Control mode.

This is accomplished by establishing an associated V/f output pattern for a given RR input level.

See RR Torque Reference #1 for further information on this setting.

This parameter sets RR Torque Reference #2 and is the output torque value that is associated with setting of RR Speed Reference #2 when operating in the Torque control mode.

This value is entered as 0.0 to 250% of the output torque range.

W7 ASD Installation and Operation Manual

Parameter Type — Numerical

Factory Default — 100.00

Changeable During Run — Yes

Minimum — 0.0

Maximum — 250.0

Units — %