Communications Reference Setpoint #1

Communications Reference Selection

Communications Reference Setpoint #1

Program Communications Settings

Communication Reference

Setpoint #1

 

When enabled via the Communications Reference Select parameter, this parameter is used to allow the user to set the gain and bias of the speed control input to the ASD when the speed control signal is received via the source selected at the Communications Reference Select parameter.

Gain and Bias Settings

When operating in the Speed Control mode and using one of the control sources from the Communications Reference Select parameter, the settings that determine the gain and bias properties of the input signal are:

Communications Speed #1 (Hz),

• the communications input signal value that represents Communications Speed #1 (Hz),

Communications Speed #2 (Hz), and

• the communications input signal value that represents Communications Speed #2 (Hz).

Once set, as the input signal value changes, the output frequency of the ASD will vary in accordance with the above settings.

This parameter sets the Communications Reference input value that represents Communications Speed #1. This value is entered as 0 to 100% of the Communications Reference input value range.

Changes made to this parameter require that the power be cycled (Off then On) for the changes to take effect.

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 100.0

Units — %

Frequency Settings

Communications Reference Setpoint #2

Program

Communications Settings

 

Comm Reference Setpoint #2

Parameter Type — Numerical

This parameter is used to set the gain and bias of the Communications

Factory Default — 100.0

 

Reference speed control input.

 

 

Changeable During Run — Yes

 

 

 

 

 

 

See Communications Reference Setpoint #1 for further information on this

Minimum — 0.00

setting.

 

 

 

 

 

 

 

 

 

 

 

This parameter sets the Communications Reference input value that represents

Maximum — 100.0

Communications Speed #2 (Hz). This value is entered as 0 to 100% of the

Units — %

Communications Reference input value range.

 

Changes made to this parameter require that the power be cycled (Off then On)

 

for the changes to take effect.

 

 

 

 

 

Communications Reference Selection

 

Program

Communications Settings

 

Communications Reference

Parameter Type — Selection List

Selection

 

 

 

 

 

Factory Default — Disabled

 

 

 

 

 

 

This parameter Enable/Disables speed control via communications. Selecting a

Changeable During Run — Yes

signal source enables this function. Selecting Disable disables this function.

 

Settings:

 

 

 

 

 

Communications

Card

 

 

RS232/RS485

 

 

 

 

LCD Keypad

 

 

 

 

Disabled

 

 

 

 

 

W7 ASD Installation

and Operation Manual

 

63

Page 69
Image 69