134 Cyclades® ACS 5000 Installation/Administration/User Guide

Field name

Definition

 

The trap type as defined in the MIB. The choices are:

 

Cold Start

 

Warm Start

Trap Number

Link Down

Link Up

 

 

Authentication Failure

 

EGP Neighbor Loss

 

Enterprise Specific

Community

The password used to authenticate the traps.

Server

The IP address of the server running the SNMP.

Body

The content of the notification.

To configure a trigger for SNMP trap notification for serial ports:

1.Go to Administration - Notifications in Expert mode, select SNMP Trap from the pull- down menu. If desired, enable Notification Alarm for Data Buffering for an alarm to sound when the trigger action occurs and click either Add or Edit. The Notifications Entry dialog box is displayed.

2.Specify the event you wish to trigger a notification for in the Alarm Trigger field.

3.If you need to edit an existing notification, select it from the pull-down list and proceed.

4.Enter or change the number in the OID Type Value field.

5.Accept the trap number or select a new one from the Trap Number pull-down menu.

6.Enter a community in the Community field.

7.Enter the IP address of the SMTP Server.

8.Enter a message in the Body text area.

9.Click OK.

10.Click apply changes.