138 Cyclades® ACS 5000 Installation/Administration/User Guide
Field Name | Definition |
| The speed of the Ethernet connection. Select the appropriate Ethernet setting if |
| you need to change the Auto Negotiation (default value): |
| 100BaseT |
Fast Ethernet | 100BaseT |
| |
| 10BaseT |
| 10BaseT |
Fast Ethernet Max. | The maximum number of packets that the CPU handles before an interrupt (0 is |
Interrupt Events | the default). |
To configure the console server boot:
1.Go to Administration - Boot Configuration in Expert mode. The Boot Configuration form displays.
2.Enter the IP address of the console server in the IP Address assigned to Ethernet field.
3.Accept or change the selected option in the Watchdog Timer field.
4.Select Flash or Network from the Unit boot from menu.
5.Select TFTP, BootP or Both from the Boot Type menu if you have selected Network from the Unit boot from in step 4.
6.Accept or change the filename of the boot program in the Boot File Name field.
7.If specifying network boot, perform the following steps:
a.Enter the IP address of the TFTP or BootP server in the Server’s IP Address field.
b.Select a console speed from the Console Speed
c.Select Skip or Full from the Flash Test
d.Select Skip, Quick or Full from the RAM Test
e.Choose an Ethernet speed from the Fast Ethernet
f.Specify the maximum number of packets that the CPU handles before an interrupt in the Fast Ethernet Max. Interrupt Events field.