Version Description
9.7(0.0) Introduced on the S6000-ON.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
Legacy E-Series
command.
Related
Commands fefd — enables far-end failure detection.
fefd mode
Change the FEFD mode on an interface.
S4820T
Syntax fefd mode {normal | aggressive}]
To return the FEFD mode to the default of normal, use the no fefd mode
command.
Parameters normal (OPTIONAL) Enter the keyword normal to change the link
state to “unknown” when a far-end failure the software
detects on that interface. When the interface is placed in
“unknown” state, the software brings down the line protocol.
aggressive (OPTIONAL) Enter the keyword aggressive to change the
link state to “error-disabled” when a far-end failure the
software detects on that interface. When an interface is
placed in “error-disabled” state, enter the fefd reset
command to reset the interface state.
Defaults normal
Command
Modes
INTERFACE
Command
History This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
8.3.19.0 Introduced on the S4820T.
Layer 2 1139