timers basic
Manipulate the RIP timers for routing updates, invalid, holddown times, and flush time.
S4820T
Syntax timers basic update invalid holddown flush
To return to the default settings, use the no timers basic command.
Parameters update Enter the number of seconds to specify the rate at which RIP
routing updates are sent. The range is from zero (0) to
4294967295. The default is 30 seconds.
invalid Enter the number of seconds to specify the time interval
before routing updates are declared invalid or expired. The
invalid value should be at least three times the update timer
value. The range is from zero (0) to 4294967295. The default
is 180 seconds.
holddown Enter the number of seconds to specify a time interval during
which the route is marked as unreachable but still sending
RIP packets. The holddown value should be at least three
times the update timer value. The range is from zero (0) to
4294967295. The default is 180 seconds.
flush Enter the number of seconds to specify the time interval
during which the route is advertised as unreachable. When
this interval expires, the route is flushed from the routing
table. The flush value should be greater than the update
value. The range is from zero (0) to 4294967295. The default
is 240 seconds.
Defaults update = 30 seconds
invalid = 180 seconds
holddown = 180 seconds
flush = 240 seconds
Command
Modes
ROUTER RIP
Command
History This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
1538 Routing Information Protocol (RIP)