Chapter 3 Modes of Operation

Table 3-4. Low-Power Mode Behavior (continued)

 

 

 

Mode

 

 

Peripheral

 

 

 

 

 

 

Stop2

Stop3

Stop4

LPwait

Wait

LPrun

 

 

 

 

 

 

 

 

Flash

Off

SoftNoClk

FullNoClk

SoftNoClk

FullNoClk

SoftOn

 

 

 

 

 

 

 

Port I/O Registers

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

ADC1,2

Off

SoftADACK

FULLADACK

SoftOn

FullOn

SoftOn

 

 

(Wake Up)

(Wake Up)

 

 

 

 

 

 

 

 

 

 

ACMPx

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

(Wake Up)

(Wake Up)

 

 

 

 

 

 

 

 

 

 

BDC

Off

SoftOn

On

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

COP

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

Crystal Oscillator

RANGE=0

RANGE=0

All Modes

RANGE=0

All Modes

RANGE=0

 

HGO=0

HGO=0

 

HGO=0

 

HGO=0

 

 

 

 

 

 

 

ICS

Off

Stop or FBELP3

Stop or any

FBELP

Any mode

FBELP

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

IICx

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

IRQ

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

(Wake Up

(Wake Up)

(Wake Up)

 

 

 

 

via POR)4

 

 

 

 

 

KBIx

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

(Wake Up)

(Wake Up)

 

 

 

 

 

 

 

 

 

 

LVD/LVW

Off

Disabled

On

Disabled

FullOn

Disabled

 

 

 

(Wake Up)

 

 

 

 

 

 

 

 

 

 

RTC

Soft

SoftOn

Full

SoftOn

FullOn

SoftOn

 

Regulation,

(Wake Up)

Regulation

 

 

 

 

LPOCLK if

 

LPOCLK,

 

 

 

 

enabled

 

ICSERCLK or

 

 

 

 

(Wake Up

 

ICSIRCLK

 

 

 

 

via POR)

 

only

 

 

 

 

 

 

(Wake Up)

 

 

 

 

 

 

 

 

 

 

SCIx

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

SPIx

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

TPMx

Off

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

Voltage Regulator / PMC

Parital

Soft Regulation.

Full

SoftOn

FullOn

SoftOn

 

Shutdown.

1 kHz osc if

Regulation

1 kHz osc on

1 kHz osc on

1 kHz osc on

 

1 kHz osc if

enabled

1 kHz osc on

 

 

 

 

enabled

 

 

 

 

 

 

 

 

 

 

 

 

LPI/O Pins

States Held

SoftNoClk

FullNoClk

SoftOn

FullOn

SoftOn

 

 

 

 

 

 

 

1LP mode for the ADC is invoked by setting ADLPC=1. ADACK is selected via the ADCCFG[ADICLK] field in the ADC. See Chapter 11, “Analog-to-Digital Converter (S08ADC12V1),” for details.

2LVD must be enabled to run in stop if converting the bandgap channel.

MCF51QE128 MCU Series Reference Manual, Rev. 3

54

Freescale Semiconductor

Get the latest version from freescale.com

Page 54
Image 54
Freescale Semiconductor MCF51QE128RM manual Bdc, Cop, Ics, Irq, Rtc