2 Signal Description
This chapter provides a detailed description of the MCH signals. The signal descriptions are arranged in functional groups according to their associated interface (see Figure 1). The states of all of the signals during reset are provided in the System Reset section.
The “#” symbol at the end of a signal name indicates that the active, or asserted state occurs when the signal is at a low voltage level. When “#” is not present after the signal name the signal is asserted when at the high voltage level.
The following notations are used to describe the signal type:
I | Input pin |
OOutput pin
I/O | |
s/t/s | Sustained |
| stating. |
as/t/s | Active Sustained |
| This pin is weakly driven to its last driven value. |
The signal description also includes the type of buffer used for the particular signal:
AGTL+ | Open Drain AGTL+ interface signal. Refer to the AGTL+ I/O Specification for |
| complete details. The MCH integrates AGTL+ termination resistors. |
AGP | AGP interface signals. These signals are compatible with AGP 2.0 1.5 V |
| Signaling Environment DC and AC Specifications. The buffers are not 3.3 V |
| tolerant. |
CMOS | CMOS buffers. |
Ref | Voltage reference signal |
Note: System address and data bus signals are logically inverted signals. In other words, the actual values are inverted of what appears on the system bus. This must be taken into account and the addresses and data bus signals must be inverted inside the MCH. All processor control signals follow normal convention. A “0” indicates an active level (low voltage) if the signal is followed by “#” symbol, and a “1” indicates an active level (high voltage) if the signal has no “#” suffix.