User-set Allocations

Section 5-3

Slave User Allocations Table

OUT block 1 area : WR (04 Hex)

First word of OUT block 1: 50 (0032 Hex)

OUT block 1 size: 20 bytes (14 Hex, 10 words)

IN block 1 area : WR (04 Hex)

First word of IN block 1: 100 (0064 Hex)

IN block 1 size: 10 bytes (0A Hex, 5 words)

Slave areas

OUT area 1

to

IN area 1

Step 1: Turn ON the Slave User Allocations Switch

Make sure that slave communications have stopped prior to performing this operation. Turn ON the Slave User Allocations Switch (word n+1, bit 11: CIO 150111 in this example). This will allocate the above areas as slave areas and the DeviceNet Unit will start slave remote I/O communications.

Step 2: Turn ON the Slave Enable Switch

Turn ON the Slave Enable Switch (word n+1, bit 06: CIO 150106 in this exam- ple). This will allocate the above areas as slave areas and the DeviceNet Unit will start slave remote I/O communications.