DeviceNet Unit FeaturesSection 1-2

1-1-5 DeviceNet Configurator

Use version 2 of the DeviceNet Configurator for the CS1W-DRM21/CJ1W- DRM21 DeviceNet Unit. Earlier versions of the DeviceNet Configurator do not support the CS1W-DRM21 DeviceNet Unit.

Product

Model

Components

 

Network connection

Applicable

OS

name

 

 

 

to computer

computer

 

 

 

 

 

 

 

DeviceNet

WS02-CFDC1-E

Installation disk

Any of the following:

IBM PC/AT or

Windows 95, 98,

Configurator

 

(CD-ROM)

Serial connection

compatible

Me, NT4.0, or

(Ver. 2)

 

 

 

2000

 

 

PCMCIA Card

 

 

 

 

 

 

 

 

 

ISA Board

 

 

 

 

 

(See the table below.)

 

 

 

 

 

 

 

 

 

Note The following Boards and Cards can be used.

Model

Components

Applicable

OS

 

 

computer

 

 

 

 

 

3G8F5-DRM21

Dedicated ISA Board with

IBM PC/AT or

Windows 95, 98, or

 

DeviceNet Configurator (Ver. 2)

compatible

NT4.0

 

 

 

 

3G8E2-DRM21

Dedicated PCMCIA Card with

 

Windows 95 or 98

 

DeviceNet Configurator (Ver. 2)

 

 

 

 

 

 

Note Use DeviceNet Configurator version 2.10 or later for the CJ1W-DRM21.

1-2

DeviceNet Unit Features

 

 

The following are features of the CS-series and CJ-series DeviceNet Units

 

 

(CS1W-DRM21 and CJ1W-DRM21).

Multi-vendor Network

Devices made by other companies (masters or slaves) can be connected to

 

 

DeviceNet because it conforms to open field network specifications. By using

 

 

a combination of valves, sensors, and other DeviceNet products, the network

 

 

can be adapted to various field-level applications.

Simultaneous Remote I/O

Remote I/O communications that constantly transfer I/O between a DeviceNet

Communications and

Unit and slaves as well as message communications where the DeviceNet

Messaging Services

Unit sends and receives data as needed can both be executed simulta-

 

 

neously. When a DeviceNet network is constructed, this feature ensures the

 

 

network will be able to handle applications that require the free flow back and

 

 

forth of bit data and message data. FINS commands can be executed along

 

 

with DeviceNet explicit messages in message communications.

Remote I/O Communications

CS/CJ-series DeviceNet

Unit (master)

Remote I/O (master) function

Slave

DeviceNet

Slave Slave

Note Refer to SECTION 4 Remote I/O Master Communications for details on remote I/O communications.

15

Page 30
Image 30