Allocated CIO Area Words

 

 

 

 

Section 3-2

 

 

 

 

 

 

 

 

 

 

 

Bit

Name

Status

Con-

Unit operation

Operation conditions

Default

 

 

 

trolled by

 

 

 

 

 

setting

 

 

 

 

CPU

Mas-

Scan

Slave

 

 

 

 

 

Unit

ter

list

func-

 

 

 

 

 

 

 

oper-

func

sta-

tion

 

 

 

 

 

 

 

ating

tion

tus

 

 

 

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

Unit Setup

OFF

User

Writes user settings (scan list, communica-

---

---

En-

---

None

 

File

ON

 

tions cycle time settings, etc.) as a file on

 

 

abled

 

 

 

 

Backup

 

 

the Memory Card in the CPU Unit. See 7-2

 

 

(See

 

 

 

 

 

 

 

 

note

 

 

 

 

Switch

 

 

Memory Card Backup Functions for details.

 

 

 

 

 

 

 

 

 

 

1.)

 

 

 

 

 

 

 

Note Files can only be backed up with

 

 

 

 

 

 

 

 

 

 

the scan list enabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Unit

Returns to OFF after the data is written to

 

 

 

 

 

 

 

 

 

 

a file.

 

 

 

 

 

 

 

 

 

 

Note The File Read/Write Error Flag

 

 

 

 

 

 

 

 

 

 

(word n+11, bit 08) in Unit Status 2

 

 

 

 

 

 

 

 

 

 

will turn ON if data failed to be writ-

 

 

 

 

 

 

 

 

 

 

ten to file.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1. When the Master function is enabled, the Unit Setup File cannot be backed up unless the scan list is enabled.

3-2-3 Master COS Send Switches (Words n+2 to n+5)

n+2

n+3

n+4

n+5

One Master COS Send Switch is allocated to each slave node address. If the switch for a slave is turned ON, then COS output data will be sent to that slave.

Bit15

Bit14

Bit13

Bit12

Bit11

Bit10

Bit09

Bit08 Bit07

Bit06

Bit05

Bit04

Bit03

Bit02

Bit01

Bit00

15

14

13

12

11

 

10

09

 

08

07

06

05

04

03

 

02

01

 

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

30

29

28

27

 

26

25

 

24

23

22

21

20

19

 

18

17

 

16

47

46

45

44

43

 

42

41

 

40

39

38

37

36

35

 

34

33

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

62

61

60

59

 

58

57

 

56

55

54

53

52

51

 

50

49

 

48

More than one of these switches may be turned ON at the same time. The switches will return to OFF starting at the switches for the slaves to which COS data has been sent.

If a send error occurs, the corresponding bit will turn ON in Slave Detailed Status.

3-2-4 Disconnect/Connect Switches (Words n+6 to n+9)

One Disconnect/Connect Switch is allocated to each slave node address. If the switch for a slave is turned ON, then remote I/O communications to that slave will be temporarily stopped (i.e., it is disconnected from the network). A communications error will occur at the end for any slave has been discon- nected if the corresponding switch is turned ON during communications.

These switches are used primarily to replace slaves or to reserve a place for a slave that will be added (when a Unit is registered in the scan list but not yet connected). A communications error and verification error for the slave that has been disconnected will not be generated at the master as long as the cor- responding switch is ON.

Note These switches do not add or remove slaves from the registered scan list.

69

Page 82
Image 82
Omron CS1W-DRM21, CJ1W-DRM21 Master COS Send Switches Words n+2 to n+5, Disconnect/Connect Switches Words n+6 to n+9