Omron CJ1W-DRM21 Error Codes and Detail Codes, Monitored and the data cannot be saved, Mrc Src

Models: CJ1W-DRM21 CS1W-DRM21

1 274
Download 274 pages 23.02 Kb
Page 229
Image 229

Error Log Functions

Section 9-2

 

When using the Configurator, the error log can be monitored with the master

 

error history read operation. With the Configurator, the error log can only be

 

monitored and the data cannot be saved.

Time Information

The CPU Unit’s time information is used for the time stamps in the DeviceNet

 

Unit’s error log records. If the time information cannot be read from the CPU

 

Unit, the time stamp will contain all zeroes.

The DeviceNet Unit’s time stamps will not be correct or consistent unless the time has been correctly in the CPU Unit. Moreover, if the battery is replaced in a CS/CJ-series CPU Unit, the time must be set again the next time that power is turned ON.

9-2-2 Error Codes and Detail Codes

Error

Error

 

 

 

Detail code

Record

code

 

 

 

 

 

 

 

stored in

 

 

First byte

 

 

Second byte

(Hex)

 

 

 

 

EEPROM

 

 

 

 

 

 

 

0001

CPU Unit watchdog timer error

00

Hex

 

 

00

Hex

Yes

 

 

 

 

 

 

0002

CPU Unit service monitoring error (The servic-

Monitoring time (ms)

 

Yes

 

ing time from the CPU Unit is not fixed.)

 

 

 

 

 

 

 

 

 

 

 

 

0006

Other CPU error

Bit 14 ON:

Duplicate unit number setting

Yes

 

 

Bit 11 ON:

Unit not in registered I/O table

 

 

 

Other bits:

Reserved for system

 

 

 

 

 

 

 

 

 

000F

CPU Unit initialization error

00

Hex

 

 

00

Hex

Yes

 

 

 

 

 

 

 

0011

Event timeout

MRC

 

 

SRC

Yes

 

 

 

 

 

 

 

 

0012

CPU Unit memory error

01

Hex: Read error

 

03

Hex: Routing table

Yes

 

 

02

Hex: Write error

 

04

Hex: CPU Bus Unit set-

 

 

 

 

 

 

 

tings error

 

 

 

 

 

 

 

05

Hex: Special Unit CIO

 

 

 

 

 

 

 

or DM allocation

 

 

 

 

 

 

 

 

 

 

219

Page 229
Image 229
Omron CJ1W-DRM21 Error Codes and Detail Codes, Monitored and the data cannot be saved, Time Information, Mrc Src