Overview of DeviceNet

 

 

 

 

 

 

Section 1-1

 

 

 

 

 

 

 

 

 

 

 

Unit

I/O

Words allocated

I/O connec-

Unit

Installa-

Model

 

Remarks

 

 

points

in PC memory

tions

power

tion

number

 

 

 

 

 

 

 

 

supply

 

 

 

 

 

 

 

Input

Output

 

 

 

 

 

 

 

 

 

voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Special

Analog

4 inputs

4 words

0 words

M3 terminal

24 VDC

DIN track

GT1-AD04

 

Inputs:

I/O Units

Input Units

 

 

 

block

(sup-

 

 

 

4 to 20 mA,

(See

 

 

 

 

 

plied

 

 

 

0 to 20 mA,

 

8 inputs

8 words

0 words

Connector

 

GT1-AD08MX

 

note.)

 

from out-

 

 

0 to 5 V,

 

 

 

 

(made by

 

 

 

 

 

 

 

 

side)

 

 

 

1 to 5 V,

 

 

 

 

 

MOLEX)

 

 

 

 

 

 

 

 

 

 

 

 

0 to 10 V,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–10 to 10 V

 

 

 

 

 

 

 

 

 

 

 

 

Analog

4 out-

0 words

4 words

M3 terminal

 

 

GT1-DA04

 

Outputs:

 

Output

puts

 

 

block

 

 

 

 

4 to 20 mA

 

Units

 

 

 

 

 

 

 

 

0 to 5 V,

 

 

 

 

 

 

 

 

 

 

1 to 5 V,

 

 

 

 

 

 

 

 

 

 

0 to 10 V,

 

 

 

 

 

 

 

 

 

 

–10 to 10 V

 

 

 

 

 

 

 

 

 

 

 

 

 

4 out-

0 words

4 words

Connector

 

 

GT1-DA04MX

 

Outputs:

 

 

puts

 

 

(made by

 

 

 

 

0 to 5 V,

 

 

 

 

 

MOLEX)

 

 

 

 

1 to 5 V,

 

 

 

 

 

 

 

 

 

 

0 to 10 V,

 

 

 

 

 

 

 

 

 

 

–10 to 10 V

 

 

 

 

 

 

 

 

 

 

 

 

Tempera-

4 inputs

4 or 8

0 words

M3 terminal

 

 

GT1-TS04T

 

Sensor

 

ture Input

 

words

 

block

 

 

 

 

types: R, S,

 

Unit

 

(varies

 

 

 

 

 

 

K, J, T, B, L

 

 

 

with

 

 

 

 

 

 

 

 

 

4 inputs

0 words

M3 terminal

 

 

GT1-TS04P

 

Sensor

 

 

data for-

 

 

 

 

 

 

 

block

 

 

 

 

types:

 

 

 

mat)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pt100,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JPt100

 

 

 

 

 

 

 

 

 

 

 

 

Counter

1 input

3 words

3 words

M3 terminal

 

 

GT1-CT01

 

1 external

 

Unit

 

 

 

block

 

 

 

 

input

 

 

 

 

 

 

 

 

 

 

2 external

 

 

 

 

 

 

 

 

 

 

outputs

 

 

 

 

 

 

 

 

 

 

 

Note The front-panel indicators and other parts of Analog Input Units, Analog Out- put Units, and Counter Units differ from those of other I/O Units. These Units belong to a group called Special I/O Units.

One I/O Unit Connecting Cable (cable length 40 mm) is included with each I/O

Unit. One end connector is attached to the Communications Unit.

I/O Unit Connecting Cables with a cable lengths of 0.1, 0.3, 0.4, 0.6, and 1 m (GCN1-010/030/040/060/100) are sold separately (see below).

Length

Note For details on MULTIPLE I/O TERMINAL Units, refer to the DeviceNet (Com- poBus/D) MULTIPLE I/O TERMINAL Operation Manual (W348).

14

Page 29
Image 29
Omron CJ1W-DRM21, CS1W-DRM21 operation manual GT1-AD08MX, GT1-DA04MX, GT1-TS04T, GT1-TS04P