User-set Allocations

Section 5-3

Connection Types and Allocated I/O Areas

The following table shows the relationship between various connection combi- nations and the allocated areas that are applicable with those connections.

Specified connection

OUT 1 area

IN 1 area

IN 2 area

type

 

 

 

 

 

 

 

Poll

Poll OUT data

Poll IN data

Not used

 

 

 

 

Bit-strobe

Not used

Bit-strobe IN data

Not used

 

 

 

 

COS

COS OUT data

COS IN data

Not used

 

 

 

 

Cyclic

Cyclic OUT data

Cyclic IN data

Not used

 

 

 

 

Poll+bit-strobe

Poll OUT data

Poll IN data

Bit-strobe IN data

 

 

 

 

Poll+COS (See note.)

Poll/COS OUT data

Poll IN data

COS IN data

 

 

 

 

Poll+cyclic (See note.)

Poll/cyclic OUT data

Poll IN data

Cyclic IN data

 

 

 

 

COS+bit-strobe

COS OUT data

COS IN data

Bit-strobe IN data

 

 

 

 

Cyclic+bit-strobe

Cyclic OUT data

Cyclic IN data

Bit-strobe IN data

 

 

 

 

Note 1. With poll + COS connections, the OUT data is the same for poll and COS. Set the same OUT areas for poll and COS connections when specifying the areas with the Configurator. With poll + cyclic connections as well, the OUT data is the same for poll and cyclic. Set the same OUT areas for poll and cyclic when specifying the areas with the Configurator.