Allocated CIO Area Words

 

 

Section 3-2

 

 

 

 

 

 

 

 

 

 

Bit

Name

Status

Con-

Unit operation

Operation condi-

Default

 

 

 

trolled

 

 

tions

 

setting

 

 

 

by

 

 

 

 

 

 

 

 

 

 

CPU

Mas-

Scan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

ter

list

 

 

 

 

 

 

 

oper-

func-

sta-

 

 

 

 

 

 

 

ating

tion

tus

 

 

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

06

Master

OFF

User

Enables master communications. (The Unit automati-

Pro-

Dis-

---

Master

 

Enable

ON

 

cally restarts.)

gram

abled

 

enabled

 

Switch

 

 

Once enabled, the Unit will function as a Master

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

regardless of whether the power is turned OFF and

 

 

 

 

 

 

 

 

 

back ON again until the Master Stop Switch (word n, bit

 

 

 

 

 

 

 

 

 

07) is turned ON.

 

 

 

 

 

 

 

 

 

Note 1. Master communications are enabled in the

 

 

 

 

 

 

 

 

 

default settings.

 

 

 

 

 

 

 

 

 

2. If this bit is turned ON with master communi-

 

 

 

 

 

 

 

 

 

cations enabled, a Unit status error will occur

 

 

 

 

 

 

 

 

 

and a C2 error will be displayed on the 7-

 

 

 

 

 

 

 

 

 

segment display. The 7-segment display will

 

 

 

 

 

 

 

 

 

go out automatically after 30 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Unit

Returns to OFF at the start of master communications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

Master

OFF

User

Stops master communications. (The Unit automatically

Pro-

En-

---

 

 

 

Stop

ON

 

restarts.)

gram

abled

 

 

 

 

Switch

 

 

Turn this switch ON if the Unit will be used only for

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

slave communications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Unit

Returns to OFF after master communications stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

Master

OFF

User

Allocates the following words for use when the scan list

Pro-

En-

Dis-

Master

 

Fixed

ON

 

is disabled (default setting). (The Unit automatically

gram

abled

abled

Fixed

 

Alloca-

 

 

restarts.)

mode

 

 

Alloca-

 

tion Set-

 

 

• OUT area: CIO 3200 to CIO 3263 (1 word/1 node ad-

 

 

 

tion

 

ting 1

 

 

 

 

 

Setting

 

 

 

dress)

 

 

 

 

Switch

 

 

 

 

 

1

 

 

 

 

• IN area: CIO 3300 to CIO 3363 (1 word/1 node ad-

 

 

 

 

 

 

 

 

 

 

 

enabled

 

 

 

 

dress)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note The I/O words used with the scan list disabled

 

 

 

 

 

 

 

 

 

are also used with the scan list enabled. (Use

 

 

 

 

 

 

 

 

 

the Scan List Enable Switch (word n, bit 00).)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Unit

Returns to OFF after the fixed allocation areas are set.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09

Master

OFF

User

Functions the same as bit 08 to allocate the following

Pro-

En-

Dis-

 

 

 

Fixed

ON

 

words. (The Unit automatically restarts.)

gram

abled

abled

 

 

 

Allocation

 

 

• OUT area: CIO 3400 to CIO 3463 (1 word/1 node ad-

mode

 

 

 

 

 

Setting 2

 

 

dress)

 

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

• IN area: CIO 3500 to CIO 3563 (1 word/1 node ad-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dress)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Unit

Returns to OFF after the fixed allocation areas are set.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Master

OFF

User

Functions the same as bit 08 to allocate the following

Pro-

En-

Dis-

 

 

 

Fixed

ON

 

words. (The Unit automatically restarts.)

gram

abled

abled

 

 

 

Alloca-

 

 

• OUT area: CIO 3600 to CIO 3663 (1 word/1 node ad-

mode

 

 

 

 

 

tion Set-

 

 

dress)

 

 

 

 

 

 

ting 3

 

 

 

 

 

 

 

 

 

 

• IN area: CIO 3700 to CIO 3763 (1 word/1 node ad-

 

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

dress)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Unit

Returns to OFF after the fixed allocation areas are set.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

Page 76
Image 76
Omron CS1W-DRM21, CJ1W-DRM21 operation manual A C2 error will be displayed on