Appendix A—Abbreviated Register Listing

 

 

63230-300-212

Register Listing

 

 

April 2001

 

 

 

 

 

 

REGISTER LISTING

 

 

 

 

Table A–3:Abbreviated Register List

 

 

 

 

 

 

 

 

 

 

Register

Description

Scale

Units

Register Range

 

Number

Factor

 

 

 

 

 

 

 

 

 

 

 

100 ms Real-Time Readings

 

 

 

 

 

 

 

 

 

 

1000

Current, Phase A

A

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1001

Current, Phase B

A

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1002

Current, Phase C

A

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1003

Current, Neutral

B

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1004

Current, Ground

C

Amps/Scale

0 to 32,767 ￿

 

 

 

 

 

 

 

1005

Current, 3-Phase Average

A

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1006

Current, Apparent RMS

A

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1020

Voltage, A-B

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1021

Voltage, B-C

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1022

Voltage, C-A

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1023

Voltage, L-L Average

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1024

Voltage, A-N

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1025

Voltage, B-N

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1026

Voltage, C-N

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1027

Voltage, N-G

E

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1028

Voltage, L-N Average

D

Volts/Scale

0 to 32,767 ￿

 

 

 

 

 

 

 

1040

Real Power, Phase A

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1041

Real Power, Phase B

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1042

Real Power, Phase C

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1043

Real Power, Total

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1044

Reactive Power, Phase A

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1045

Reactive Power, Phase B

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1046

Reactive Power, Phase C

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1047

Reactive Power, Total

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1048

Apparent Power, Phase A

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1049

Apparent Power, Phase B

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1050

Apparent Power, Phase C

F

kVA/Scale

-32,767 to 32,767 ￿

 

 

 

 

 

 

 

1051

Apparent Power, Total

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1060

True Power Factor, Phase A

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

1061

True Power Factor, Phase B

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

1062

True Power Factor, Phase C

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

1063

True Power Factor, Total

0.001

-100 to 1,000 to 100

￿

 

 

 

 

 

1064

Alternate True Power Factor, Phase A

0.001

0 to 2,000

￿

 

 

 

 

 

See “How Power Factor is Stored in the Register” on page 128.

 

 

￿￿

 

 

 

 

 

The alternate storage method for power factor (PF) is useful for outputting PF on analog outputs. The PF value is stored as a positive value between 0 and 2, centered around 1 (unity). A value of 0 lagging maps to 0; -0.999 maps to 0.999;0.999 leading maps to 1.001; and 0 leading maps to 2. The alternate PF is also stored with a scale factor 0.001.

These configuration registers require that you enter the setup mode to change the register’s contents. Issue command 9020 to enter setup mode and 9021 to exit setup mode. See “Using the Command Interface to Change Configuration Registers” on page 187 for instructions on

￿how to use the setup-mode commands.

Quantity available for 4-wire system only. Value set to -32,768 if not available.

130

© 2001 Schneider Electric All Rights Reserved

Page 142
Image 142
Schneider Electric 4000 manual Register Listing, Table A-3Abbreviated Register List